<mets:mets OBJID="eprint_1433" LABEL="Eprints Item" xsi:schemaLocation="http://www.loc.gov/METS/ http://www.loc.gov/standards/mets/mets.xsd http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-3.xsd" xmlns:mets="http://www.loc.gov/METS/" xmlns:mods="http://www.loc.gov/mods/v3" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"><mets:metsHdr CREATEDATE="2017-11-01T00:54:35Z"><mets:agent ROLE="CUSTODIAN" TYPE="ORGANIZATION"><mets:name>WIT Repository</mets:name></mets:agent></mets:metsHdr><mets:dmdSec ID="DMD_eprint_1433_mods"><mets:mdWrap MDTYPE="MODS"><mets:xmlData><mods:titleInfo><mods:title>Inclusion of Interactions in Mathematical Modelling of Implant Assisted Magnetic Drug Targeting</mods:title></mods:titleInfo><mods:name type="personal"><mods:namePart type="given">Adil</mods:namePart><mods:namePart type="family">Mardinoglu</mods:namePart><mods:role><mods:roleTerm type="text">author</mods:roleTerm></mods:role></mods:name><mods:abstract>Drug delivery technologies are an important area within biomedicine. Targeted drug delivery aims to reduce the undesired side effects of drug usage by directing or capturing the active agents near a desired site within the body. This is particularly beneficial in, for instance, cancer chemotherapy, where the side effects of general (systemic) drug administration can be severe.
One approach to targeted drug delivery uses magnetic nanoparticles as the constituents of carriers for the desired active agent. Once injected into the body, the behaviour of these magnetic carriers can be influenced and controlled by magnetic fields. In implant assisted magnetic drug targeting systems a magnetic implant, typically a stent, wire or spherical seed can be used to target sites deep within the body as the implant acts as a focus for the resulting magnetic force. This can be easily understood as the force depends on the gradient of the magnetic field and the gradient near the implant is large. 
In designing such a system many factors need to be considered including physical factors such as the size and nature of the implants and carriers, and the fields required. Moreover the range of applicability of these systems in terms of the regions of the vasculature system, from low blood velocity environments, such as capillary beds to higher velocity arteries, must be considered. Furthermore, assessment criteria for these systems are needed. Mathematical modelling and simulation has a valuable role to play in informing in vitro and in vivo experiments, leading to practical system design.
Specifically, the implant assisted magnetic drug targeting systems of Avil´es, Ebner and Ritter are considered within this work, and two dimensional mathematical modelling is performed using the open source C++ finite volume library OpenFOAM. In the first system treated, a large ferromagnetic particle is implanted into a capillary bed as a seed to aid collection of single domain nanoparticles (radius 20-100 nm). The Langevin function is used to calculate the magnetic moment of the particles, and the model is further adapted to treat the agglomeration of particles known to occur in these systems. This agglomeration can be attributed to interparticle interactions and here the magnetic dipole-dipole and hydrodynamic interactions for two mutually interacting nanoparticles are modelled, following Mikkelsen et al. who treated two particle interactions in microfluidic systems, with low magnetic field (0.05 T). The resulting predicted performance is found to both increase and decrease significantly depending on initial positions of the particles. Secondly, a ferromagnetic, coiled wire stent is implanted in a large arterial vessel. The magnetic dipole-dipole and hydrodynamic interactions for multiple (N &lt; 20) particles are included. Different initial positions are considered and the system performance is assessed. Inclusion of these interactions yields predictions that are in closer agreement with the experimental results of Avil´es et al.. We conclude that the discrepancies between the non interacting theoretical predictions and the corresponding experimental results can (as suggested by Avil´es et al.) be largely attributed to interparticle interactions and the consequent agglomeration.</mods:abstract><mods:classification authority="lcc">*NONE OF THESE*</mods:classification><mods:originInfo><mods:dateIssued encoding="iso8061">2009-11</mods:dateIssued></mods:originInfo><mods:originInfo><mods:publisher>Waterford Institute of Technology;School of Engineering</mods:publisher></mods:originInfo><mods:genre>Thesis</mods:genre></mets:xmlData></mets:mdWrap></mets:dmdSec><mets:amdSec ID="TMD_eprint_1433"><mets:rightsMD ID="rights_eprint_1433_mods"><mets:mdWrap MDTYPE="MODS"><mets:xmlData><mods:useAndReproduction>
<p xmlns="http://www.w3.org/1999/xhtml"><strong>For work being deposited by its own author:</strong> 
In self-archiving this collection of files and associated bibliographic 
metadata, I grant WIT Repository the right to store 
them and to make them permanently available publicly for free on-line. 
I declare that this material is my own intellectual property and I 
understand that WIT Repository does not assume any 
responsibility if there is any breach of copyright in distributing these 
files or metadata. (All authors are urged to prominently assert their 
copyright on the title page of their work.)</p>

<p xmlns="http://www.w3.org/1999/xhtml"><strong>For work being deposited by someone other than its 
author:</strong> I hereby declare that the collection of files and 
associated bibliographic metadata that I am archiving at 
WIT Repository) is in the public domain. If this is 
not the case, I accept full responsibility for any breach of copyright 
that distributing these files or metadata may entail.</p>

<p xmlns="http://www.w3.org/1999/xhtml">Clicking on the deposit button indicates your agreement to these 
terms.</p>
    </mods:useAndReproduction></mets:xmlData></mets:mdWrap></mets:rightsMD></mets:amdSec><mets:fileSec><mets:fileGrp USE="reference"><mets:file ID="eprint_1433_849_1" SIZE="2782806" OWNERID="http://repository.wit.ie/1433/1/Inclusion_of_Interactions_in_Mathematical_Modelling_of_Implant_Assisted_Magnetic_Drug_Targeting.pdf" MIMETYPE="application/pdf"><mets:FLocat LOCTYPE="URL" xlink:type="simple" xlink:href="http://repository.wit.ie/1433/1/Inclusion_of_Interactions_in_Mathematical_Modelling_of_Implant_Assisted_Magnetic_Drug_Targeting.pdf"></mets:FLocat></mets:file></mets:fileGrp></mets:fileSec><mets:structMap><mets:div DMDID="DMD_eprint_1433_mods" ADMID="TMD_eprint_1433"><mets:fptr FILEID="eprint_1433_document_849_1"></mets:fptr></mets:div></mets:structMap></mets:mets>